Water Units

Compact temperature control systemTT-170 L

Moulds up to 50 Kg, rollers up to 80 mm Ø, length 300 mm

Eckdaten

  • Maximum temperature 90°C
  • Medium water
  • Heating capacity 3 kW
  • Cooling capacity 30 kW @ 90°C
  • Cooling system indirect
  • Pump capacity 28 l/min; max. 2.8 bar

Functions

  • Self-optimizing temperature controller with temperature display
    1/10°C – steps
  • Display in °C or °F and l/min or gal/min
  • Automatic temperature control
  • Automatic water filling

Construction

  • Submersible sealless pump made from bronze
  • Limescale free heat exchanger
  • Corrosion resistant device for a long service life
  • All parts in contact with water are made of stainless steel or bronze
  • Unit on castors

Safety features

  • Level control for dry run protection
  • Electronic temperature limitation and monitoring in the controller
  • Mechanical safety thermostat
  • Visual and acoustic fault indications
  • Integrated circuit breakers
  • Main switch, transformer and motor protection switch

Cooling capacity

Pump capacity

Product informationsTT-170 L

ProductTT-170 L
Temperature range°C90
Heat transfer mediumwater
   Filling amount max.l5
Heating capacitykW3
Cooling systemindirect
   tubular heat exchangerkW30
   Plate heat exchangerkW
   DirectkW
   At flow temperature°C90
Pump system see diagram
   Typ L: 19 l/min; max. 2.9 bar; motor 0.27 kW
   Typ E: 60 l/min; max. 4.0 bar; motor 0.75 kW
   Typ H: 60 l/min; max. 7.0 bar; motor 1.50 kW
   Typ K: 200 l/min; max. 4.3 bar; motor 2.2 kW
   Typ W: 250-350 l/min; max. 4.5 bar; motor 4.0 kW
   Typ V: 580 l/min; max. 4.1 bar; motor 7.5 kW
   Suction capacity vakuummWS-
ControllerMP-888
   Measurement typeFeKo Typ J
Connections
   Medium3/8" BS
   Cooling water3/8" BS
   Compressed air-
Dimensions incl. castors, LxWxHmm640x200x490
Weight empty approx.kg36
Coloursilvergrey RAL 7001
 
Functions● standard/ ○ optional / - not possible
Flow control-
Leakstopper device-
Mould drain-
Temperature control at the consumer-
Time limited water refill-
Interface controller-
Automatic refill
Level control
Visual fault indications
Acoustic warning
Pressure regulation-